Data:    
SOFC type: SOFC-HELP  
Power-electrical 100 Watt electrical
Efficiency-electrical 48 %
Power-thermal 108 Watt thermal
Total Fuel Cell System Investment 900  
Gas price in NL 0,05 EUR/kWh(thermal)
Electricity price in NL 0,19 EUR/kWh(electrical)
     
Thermal efficiency of conventional combustion 85 %
     
Calculations:    
  kWh/year EUR/year
Electrical yield 876 166
Thermal 949 47
Total SOFC yield   214
     
Gas feed cost 1825 91
Thermal conversion of conventional combustion 1551 77
     
Profit in EUR/year   123
Profit in EUR/year compared to combustion   136
     
Pay back time in years   7,3
Payback time in years compared to combustion   6,6
Conclusion: Profitable, while the payback time is well within the expected life time of >10 years.